Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 183
Filtrar
1.
Am J Clin Pathol ; 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507618

RESUMO

OBJECTIVES: Complete blood count and differential (CBC diff) is a common laboratory test that may be overused or misordered, particularly in an inpatient setting. We assessed the ability of a clinical decision support (CDS) alert to decrease unnecessary orders for CBC diff and analyzed its impact in the laboratory. METHODS: We designed 3 CDS alerts to provide guidance to providers ordering CBC diff on inpatients at frequencies of daily, greater than once daily, or as needed. RESULTS: The 3 alerts were highly effective in reducing orders for CBC diff at the frequencies targeted by the alert. Overall, test volume for CBC diff decreased by 32% (mean of 5257 tests per month) after implementation of the alerts, with a corresponding decrease of 22% in manual differentials performed (mean of 898 per month). Turnaround time for manual differentials decreased by a mean of 41.5 minutes, with a mean decrease of up to 90 minutes during peak morning hours. CONCLUSIONS: The 3 CDS alerts successfully decreased inpatient orders for CBC diff and improved the quality of patient care by decreasing turnaround time for manual differentials.

2.
Int J Nurs Stud ; 151: 104671, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38237323

RESUMO

BACKGROUND: Appropriate care escalation requires the detection and communication of in-hospital patient deterioration. Although deterioration in the ward environment is common, there continue to be patient deaths where problems escalating care have occurred. Learning from the everyday work of health care professionals (work-as-done) and identifying performance variability may provide a greater understanding of the escalation challenges and how they overcome these. The aims of this study were to i) develop a representative model detailing escalation of care ii) identify performance variability that may negatively or positively affect this process and iii) examine linkages between steps in the escalation process. METHODS: Thirty Applied Cognitive Task Analysis interviews were conducted with clinical experts (>4 years' experience) including Ward Nurses (n = 7), Outreach or Sepsis Nurses (n = 8), Nurse Manager or Consultant (n = 6), Physiotherapists (n = 4), Advanced Practitioners (n = 4), and Doctor (n = 1) from two National Health Service hospitals and analysed using Framework Analysis. Task-related elements of care escalation were identified and represented in a Functional Resonance Analysis Model. FINDINGS: The NEWS2's clinical escalation response constitutes eight unique tasks and illustrates work-as-prescribed, but our interview data uncovered an additional 24 tasks (n = 32) pertaining to clinical judgement, decisions or processes reflecting work-as-done. Over a quarter of these tasks (9/32, 28 %) were identified by experts as cognitively challenging with a high likelihood of performance variability. Three out of the nine variable tasks were closely coupled and interdependent within the Functional Resonance Analysis Model ('synthesising data points', 'making critical decision to escalate' and 'identifying interim actions') so representing points of potential escalation failure. Data assimilation from different clinical information systems with poor usability was identified as a key cognitive challenge. CONCLUSION: Our data support the emphasis on the need to retain clinical judgement and suggest that future escalation protocols and audit guidance require in-built flexibility, supporting staff to incorporate their expertise of the patient condition and the clinical environment. Improved information systems to synthesise the required data surrounding an unwell patient to reduce staff cognitive load, facilitate decision-making, support the referral process and identify actions are required. Fundamentally, reducing the cognitive load when assimilating core escalation data allows staff to provide better and more creative care. Study registration (ISRCTN 38850) and ethical approval (REC Ref 20/HRA/3828; CAG-20CAG0106).


Assuntos
Pacientes Internados , Medicina Estatal , Humanos , Hospitais , Comunicação , Cognição
4.
J Radiat Res ; 65(1): 136-143, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38037422

RESUMO

We demonstrate the application of fluorescence optical fiber coupled to a telecom grade fiber as a sensor for alpha particles using alpha-specific ZnS(Ag) scintillation materials whose wavelength is down-shifted into a low-loss region of the telecom grade fiber transmission band. Telecom-grade fiber optics offer a solution for sensing alpha radiation in deep repositories and cask storage for radioactive materials due to the stability of SiO2 under normal environmental conditions and its relative radiation hardness at low radiation doses. Long-term nuclear waste storage facilities require sensors for the detection of leakage of radioactive materials that are maintenance-free, do not require power and can survive with no 'wear out' mechanisms for decades. By accomplishing the wavelength transformation, we maximize efficiencies in the detection of α-particles and signal transport and can detect alpha scintillation at distances on the order of >1 km with a sensor that is ~3% efficient and can be easily scaled as a sensor array. This paper describes the construction and testing of the sensor including manufacture of the controlled thickness films, verification of the wavelength shift from 450 to 620 nm and optimization of the sensitivity as a function of thickness. We also model the relative sensitivity of the film as a function of film thickness, and we demonstrate a signal-to-noise ratio of 10 at a range of greater than 1 km.


Assuntos
Partículas alfa , Fibras Ópticas , Dióxido de Silício , Tecnologia de Fibra Óptica
5.
Cancer Cell ; 40(9): 999-1009.e6, 2022 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-36055228

RESUMO

Cancer patients benefit from early tumor detection since treatment outcomes are more favorable for less advanced cancers. Platelets are involved in cancer progression and are considered a promising biosource for cancer detection, as they alter their RNA content upon local and systemic cues. We show that tumor-educated platelet (TEP) RNA-based blood tests enable the detection of 18 cancer types. With 99% specificity in asymptomatic controls, thromboSeq correctly detected the presence of cancer in two-thirds of 1,096 blood samples from stage I-IV cancer patients and in half of 352 stage I-III tumors. Symptomatic controls, including inflammatory and cardiovascular diseases, and benign tumors had increased false-positive test results with an average specificity of 78%. Moreover, thromboSeq determined the tumor site of origin in five different tumor types correctly in over 80% of the cancer patients. These results highlight the potential properties of TEP-derived RNA panels to supplement current approaches for blood-based cancer screening.


Assuntos
Neoplasias , RNA , Biomarcadores Tumorais/genética , Plaquetas , Detecção Precoce de Câncer/métodos , Humanos , Neoplasias/diagnóstico , Neoplasias/genética , RNA/genética
6.
Int J Nurs Stud ; 131: 104242, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35525086

RESUMO

BACKGROUND: Pre-COVID-19 research highlighted the nursing profession worldwide as being at high risk from symptoms of burnout, post-traumatic stress disorder (PTSD) and suicide. The World Health Organization declared a pandemic on 11th March 2020 due to the sustained risk of further global spread of COVID-19. The high healthcare burden associated with COVID-19 has increased nurses' trauma and workload, thereby exacerbating pressure on an already strained workforce and causing additional psychological distress for staff. OBJECTIVES: The Impact of COVID-19 on Nurses (ICON) interview study examined the impacts of the pandemic on frontline nursing staff's psychosocial and emotional wellbeing. DESIGN: Longitudinal qualitative interview study. SETTINGS: Nurses who had completed time 1 and 2 of the ICON survey were sampled to include a range of UK work settings including acute, primary and community care and care homes. Interviewees were purposively sampled for maximum variation to cover a broad range of personal and professional factors, and experiences during the COVID-19 pandemic, including redeployment. METHODS: Nurses participated in qualitative in-depth narrative interviews after the first wave of COVID-19 in July 2020 (n = 27) and again at the beginning of the second wave in December 2020 (n = 25) via video and audio platform software. Rigorous qualitative narrative analysis was undertaken both cross-sectionally (within wave) and longitudinally (cross wave) to explore issues of consistency and change. RESULTS: The terms moral distress, compassion fatigue, burnout and PTSD describe the emotional states reported by the majority of interviewees leading many to consider leaving the profession. Causes of this identified included care delivery challenges; insufficient staff and training; PPE challenges and frustrations. Four themes were identified: (1) 'Deathscapes' and impoverished care (2) Systemic challenges and self-preservation (3) Emotional exhaustion and (4) (Un)helpful support. CONCLUSIONS: Nurses have been deeply affected by what they have experienced and report being forever altered with the impacts of COVID-19 persisting and deeply felt. There is an urgent need to tackle stigma to create a psychologically safe working environment and for a national COVID-19 nursing workforce recovery strategy to help restore nurse's well-being and demonstrate a valuing of the nursing workforce and therefore support retention.


Assuntos
Esgotamento Profissional , COVID-19 , Enfermeiras e Enfermeiros , Esgotamento Profissional/psicologia , Humanos , Pandemias , Pesquisa Qualitativa , Reino Unido
7.
Clin Chim Acta ; 531: 204-211, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35341764

RESUMO

BACKGROUND: To select and standardize point-of-care (POC) glucose meters across a multi-hospital system. METHODS: We formed a multidisciplinary POC glucose standardization working group including key stakeholders from each site. A set of selection criteria: usability, clinical and laboratory performance, indications for use, interface connectivity, ease of implementation and ongoing operational costs were used to develop a scoring schemato facilitate a consensus-driven selection process. RESULTS: Method comparison and consensus error grid evaluation against the clinically validated reference methods demonstrated that the analytical performance for all candidate meters was comparable for both the laboratory and clinical evaluation. However, Meter 1 ranked highest in usability evaluations, implementation and streamlined interface connectivity. The meter selection process and implementation were staggered across sites due to complexity of transitioning to a new manufacturer's meter and limitations in vendor support for training and ongoing troubleshooting of interface connectivity. CONCLUSIONS: Standardization of POC glucose meters in a large multi-hospital system is a complex undertaking requiring robust, multidisciplinary organizational structure both system-wide and locally, development of consensus-driven selection tools, usability evaluation by end-users, laboratory and clinical evaluation of the analytical performance, and a strong vendor-laboratory partnership during the implementation process.


Assuntos
Glicemia , Glucose , Automonitorização da Glicemia , Hospitais , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Padrões de Referência
8.
J Appl Psychol ; 107(3): 481-502, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34110850

RESUMO

In this article we explore the effect of encounters with rudeness on the tendency to engage in anchoring, one of the most robust and widespread cognitive biases. Integrating the self-immersion framework with the selective accessibility model (SAM), we propose that rudeness-induced negative arousal will narrow individuals' perspectives in a way that will make anchoring more likely. Additionally, we posit that perspective taking and information elaboration will attenuate the effect of rudeness on both negative arousal and subsequent anchoring. Across four experimental studies, we test the impact of exposure to rudeness on anchoring as manifested in a variety of tasks (medical diagnosis, judgment tasks, and negotiation). In a pilot study, we find that rudeness is associated with anchoring among a group of medical students making a medical diagnosis. In Study 1, we show that negative arousal mediates the effect of rudeness on anchoring among medical residents treating a patient, and that perspective taking moderates these effects. Study 2 replicates the results of Study 1 using a common anchoring task, and Study 3 builds on these results by replicating them in a negotiation setting and testing information elaboration as a boundary condition. Across the four studies, we find consistent evidence that rudeness-induced negative arousal leads to anchoring, and that these effects can be mitigated by perspective taking and information elaboration. (PsycInfo Database Record (c) 2022 APA, all rights reserved).


Assuntos
Incivilidade , Humanos , Julgamento , Projetos Piloto
9.
Comput Biol Med ; 135: 104522, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34153792

RESUMO

There has been a growing interest in developing electric impedance sensing surgical tools for tissue identification during surgery. A key facet of this development is identifying distinct features that can be used to identify tissues from one another. This paper explores several feature extraction techniques and classification methods applied to electric impedance data. Furthermore, a modified forward stepwise method is proposed. The method introduces a scoring metric to help select features to add to the model, that is based off of the coefficient of variation and overlapping index from the feature's probability density functions for each of the classes. The proposed and existing methods were applied to spectral data measured at 23 frequencies, from 132 samples across 6 different tissues including ex-vivo bovine kidney, liver and muscle, poultry liver, as well as freshly excised canine testicle and ovary samples. These methods were able to successfully find impedance spectra features for the investigated biological tissues. The best predictive accuracy was with Boruta feature extraction and a Random Forest classifier but without significantly reducing the number of features in the classifier model. The proposed method was able to reduce the number of features in the model to an average of 5.8 features for all tested classifiers. These methods may have use in finding features to discriminate other tissue types, possibly to aid in targeting lesions in minimally invasive cancer treatment surgeries.


Assuntos
Espectroscopia Dielétrica , Agulhas , Animais , Bovinos , Cães , Impedância Elétrica , Eletrodos , Feminino , Rim
10.
Clin Infect Dis ; 70(6): 1215-1221, 2020 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-31044232

RESUMO

BACKGROUND: Anaplasmosis presents with fever, headache, and laboratory abnormalities including leukopenia and thrombocytopenia. Polymerase chain reaction (PCR) is the preferred diagnostic but is overutilized. We determined if routine laboratory tests could exclude anaplasmosis, improving PCR utilization. METHODS: Anaplasma PCR results from a 3-year period, with associated complete blood count (CBC) and liver function test results, were retrospectively reviewed. PCR rejection criteria, based on white blood cell (WBC) and platelet (PLT) counts, were developed and prospectively applied in a mock stewardship program. If rejection criteria were met, a committee mock-refused PCR unless the patient was clinically unstable or immunocompromised. RESULTS: WBC and PLT counts were the most actionable routine tests for excluding anaplasmosis. Retrospective review demonstrated that rejection criteria of WBC ≥11 000 cells/µL or PLT ≥300 000 cells/µL would have led to PCR refusal in 428 of 1685 true-negative cases (25%) and 3 of 66 true-positive cases (5%) involving clinically unstable or immunocompromised patients. In the prospective phase, 155 of 663 PCR requests (23%) met rejection criteria and were reviewed by committee, which endorsed refusal in 110 of 155 cases (71%) and approval in 45 (29%), based on clinical criteria. PCR was negative in all 45 committee-approved cases. Only 1 of 110 mock-refused requests yielded a positive PCR result; this patient was already receiving doxycycline at the time of testing. CONCLUSIONS: A CBC-based stewardship algorithm would reduce unnecessary Anaplasma PCR testing, without missing active cases. Although the prospectively evaluated screening approach involved medical record review, this was unnecessary to prevent errors and could be replaced by a rejection comment specifying clinical situations that might warrant overriding the algorithm.


Assuntos
Anaplasma phagocytophilum , Anaplasmose , Anaplasma phagocytophilum/genética , Anaplasmose/diagnóstico , Animais , Contagem de Células Sanguíneas , Técnicas e Procedimentos Diagnósticos , Humanos , Estudos Prospectivos , Estudos Retrospectivos
12.
Appl Clin Inform ; 9(3): 519-527, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29998456

RESUMO

OBJECTIVES: Laboratory-based utilization management programs typically rely primarily on data derived from the laboratory information system to analyze testing volumes for trends and utilization concerns. We wished to examine the ability of an electronic health record (EHR) laboratory orders database to improve a laboratory utilization program. METHODS: We obtained a daily file from our EHR containing data related to laboratory test ordering. We then used an automated process to import this file into a database to facilitate self-service queries and analysis. RESULTS: The EHR laboratory orders database has proven to be an important addition to our utilization management program. We provide three representative examples of how the EHR laboratory orders database has been used to address common utilization issues. We demonstrate that analysis of EHR laboratory orders data has been able to provide unique insights that cannot be obtained by review of laboratory information system data alone. Further, we provide recommendations on key EHR data fields of importance to laboratory utilization efforts. CONCLUSION: We demonstrate that an EHR laboratory orders database may be a useful tool in the monitoring and optimization of laboratory testing. We recommend that health care systems develop and maintain a database of EHR laboratory orders data and integrate this data with their laboratory utilization programs.


Assuntos
Técnicas de Laboratório Clínico , Bases de Dados Factuais , Registros Eletrônicos de Saúde , Projetos de Pesquisa , Humanos
13.
Am J Clin Pathol ; 150(2): 96-104, 2018 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-29850771

RESUMO

OBJECTIVES: In the United States, minimum standards for quality control (QC) are specified in federal law under the Clinical Laboratory Improvement Amendment and its revisions. Beyond meeting this required standard, laboratories have flexibility to determine their overall QC program. METHODS: We surveyed chemistry and immunochemistry QC procedures at 21 clinical laboratories within leading academic medical centers to assess if standardized QC practices exist for chemistry and immunochemistry testing. RESULTS: We observed significant variation and unexpected similarities in practice across laboratories, including QC frequency, cutoffs, number of levels analyzed, and other features. CONCLUSIONS: This variation in practice indicates an opportunity exists to establish an evidence-based approach to QC that can be generalized across institutions.


Assuntos
Centros Médicos Acadêmicos/normas , Química Clínica/normas , Serviços de Laboratório Clínico/normas , Imunoquímica/normas , Controle de Qualidade , Humanos , Laboratórios/normas , Inquéritos e Questionários , Estados Unidos
14.
Clin Cancer Res ; 24(20): 5058-5071, 2018 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-29898992

RESUMO

Purpose: In the proper context, radiotherapy can promote antitumor immunity. It is unknown if elective nodal irradiation (ENI), a strategy that irradiates tumor-associated draining lymph nodes (DLN), affects adaptive immune responses and combinatorial efficacy of radiotherapy with immune checkpoint blockade (ICB).Experimental Design: We developed a preclinical model to compare stereotactic radiotherapy (Tumor RT) with or without ENI to examine immunologic differences between radiotherapy techniques that spare or irradiate the DLN.Results: Tumor RT was associated with upregulation of an intratumoral T-cell chemoattractant chemokine signature (CXCR3, CCR5-related) that resulted in robust infiltration of antigen-specific CD8+ effector T cells as well as FoxP3+ regulatory T cells (Tregs). The addition of ENI attenuated chemokine expression, restrained immune infiltration, and adversely affected survival when combined with ICB, especially with anti-CLTA4 therapy. The combination of stereotactic radiotherapy and ICB led to long-term survival in a subset of mice and was associated with favorable CD8 effector-to-Treg ratios and increased intratumoral density of antigen-specific CD8+ T cells. Although radiotherapy technique (Tumor RT vs. ENI) affected initial tumor control and survival, the ability to reject tumor upon rechallenge was partially dependent upon the mechanism of action of ICB; as radiotherapy/anti-CTLA4 was superior to radiotherapy/anti-PD-1.Conclusions: Our results highlight that irradiation of the DLN restrains adaptive immune responses through altered chemokine expression and CD8+ T-cell trafficking. These data have implications for combining radiotherapy and ICB, long-term survival, and induction of immunologic memory. Clinically, the immunomodulatory effect of the radiotherapy strategy should be considered when combining stereotactic radiotherapy with immunotherapy. Clin Cancer Res; 24(20); 5058-71. ©2018 AACR.


Assuntos
Imunoterapia , Linfonodos/patologia , Linfonodos/efeitos da radiação , Neoplasias/patologia , Neoplasias/terapia , Radiocirurgia , Transferência Adotiva , Animais , Linhagem Celular Tumoral , Terapia Combinada , Citocinas/metabolismo , Modelos Animais de Doenças , Humanos , Imunoterapia/métodos , Linfonodos/imunologia , Linfonodos/metabolismo , Linfócitos do Interstício Tumoral/imunologia , Linfócitos do Interstício Tumoral/metabolismo , Linfócitos do Interstício Tumoral/patologia , Melanoma Experimental , Camundongos , Neoplasias/imunologia , Neoplasias/metabolismo , Prognóstico , Radiocirurgia/métodos , Especificidade do Receptor de Antígeno de Linfócitos T , Subpopulações de Linfócitos T/imunologia , Subpopulações de Linfócitos T/metabolismo , Ensaios Antitumorais Modelo de Xenoenxerto
15.
Blood Coagul Fibrinolysis ; 29(2): 184-188, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29356700

RESUMO

: Coagulation laboratories have largely stopped transporting whole blood specimens on ice, due to adverse effects on factor VIII, von Willebrand factor, and the prothrombin time. However, it is unknown whether ice should be required or avoided for other coagulation assays. Furthermore, the amount of time that specimens remain stable during transportation at room temperature (RT) is also largely unknown for many coagulation tests. Therefore, this study investigated specimen stability on ice and RT for a comprehensive panel of coagulation tests. One tube of whole blood from each volunteer (n = 22) was centrifuged immediately (time 0), one was stored for 4 h on ice, and one was stored for 4 h at RT before centrifugation. Among time 0, 4 h on ice, and 4 h at RT samples, no statistically significant differences were found for fibrinogen, activated protein C resistance, thrombin time, reptilase time, antithrombin activity, chromogenic protein C, factor XII, and antiplasmin activity. Prothrombin time, activated partial thromboplastin time, factors IX, XI, protein S activity, and plasminogen activity showed statistically, but not clinically, significant differences. On ice, the only analytes that showed clinically significant changes (≥6.0% from time 0) were factors VII, VIII, von Willebrand factor antigen, and ristocetin cofactor, which were 14.0% higher, and 19.2, 9.5, and 18.8% lower than time 0, respectively. At RT, all analytes were stable except factor VIII was 9.4% lower than time 0. Only factors II, V, X, and PTT-LA lupus anticoagulant showed a possible slight benefit from ice, but the statistically significant differences were not clinically significant. Ice did not substantially benefit any of the coagulation assays. All tests were stable at RT, except more study is needed regarding factor VIII.


Assuntos
Fatores de Coagulação Sanguínea/metabolismo , Testes de Coagulação Sanguínea/métodos , Temperatura Baixa , Humanos , Fatores de Tempo
16.
Chemosphere ; 192: 337-347, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29121563

RESUMO

This study utilized probabilistic risk assessment techniques to compare field sediment concentrations of the cyclic volatile methylsiloxane (cVMS) materials octamethylcyclotetrasiloxane (D4, CAS # 556-67-2), decamethylcyclopentasiloxane (D5, CAS # 541-02-6), and dodecamethylcyclohexasiloxane (D6, CAS # 540-97-6) to effect levels for these compounds determined in laboratory chronic toxicity tests with benthic organisms. The concentration data for D4/D5/D6 in sediment were individually sorted and the 95th centile concentrations determined in sediment on an organic carbon (OC) fugacity basis. These concentrations were then compared to interpolated 5th centile benthic sediment no-observed effect concentration (NOEC) fugacity levels, calculated from a distribution of chronic D4/D5/D6 toxicologic assays per OECD guidelines using a variety of standard benthic species. The benthic invertebrate fugacity biota NOEC values were then compared to field-measured invertebrate biota fugacity levels to see if risk assessment evaluations were similar on a field sediment and field biota basis. No overlap was noted for D4 and D5 95th centile sediment and biota fugacity levels and their respective 5th centile benthic organism NOEC values. For D6, there was a small level of overlap at the exposure 95th centile sediment fugacity and the 5th centile benthic organism NOEC fugacity value; the sediment fugacities indicate that a negligible risk (1%) exists for benthic species exposed to D6. In contrast, there was no indication of risk when the field invertebrate exposure 95th centile biota fugacity and the 5th centile benthic organism NOEC fugacity values were compared.


Assuntos
Medição de Risco/métodos , Siloxanas/toxicidade , Poluentes Químicos da Água/toxicidade , Animais , Biota/efeitos dos fármacos , Invertebrados/efeitos dos fármacos , Poluentes Químicos da Água/análise
17.
Am J Clin Pathol ; 148(2): 128-135, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28898984

RESUMO

OBJECTIVES: We sought to address concerns regarding recurring inpatient laboratory test order practices (daily laboratory tests) through a multifaceted approach to changing ordering patterns. METHODS: We engaged in an interdepartmental collaboration to foster mindful test ordering through clinical policy creation, electronic clinical decision support, and continuous auditing and feedback. RESULTS: Annualized daily order volumes decreased from approximately 25,000 to 10,000 during a 33-month postintervention review. This represented a significant change from preintervention order volumes (95% confidence interval, 0.61-0.64; P < 10-16). Total inpatient test volumes were not affected. CONCLUSIONS: Durable changes to inpatient order practices can be achieved through a collaborative approach to utilization management that includes shared responsibility for establishing clinical guidelines and electronic decision support. Our experience suggests auditing and continued feedback are additional crucial components to changing ordering behavior. Curtailing daily orders alone may not be a sufficient strategy to reduce in-laboratory costs.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Testes Diagnósticos de Rotina/estatística & dados numéricos , Sistemas de Registro de Ordens Médicas , Padrões de Prática Médica/estatística & dados numéricos , Centros Médicos Acadêmicos , Humanos , Laboratórios Hospitalares/estatística & dados numéricos , Procedimentos Desnecessários/estatística & dados numéricos
18.
Cancer Cell ; 32(2): 238-252.e9, 2017 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-28810146

RESUMO

Blood-based liquid biopsies, including tumor-educated blood platelets (TEPs), have emerged as promising biomarker sources for non-invasive detection of cancer. Here we demonstrate that particle-swarm optimization (PSO)-enhanced algorithms enable efficient selection of RNA biomarker panels from platelet RNA-sequencing libraries (n = 779). This resulted in accurate TEP-based detection of early- and late-stage non-small-cell lung cancer (n = 518 late-stage validation cohort, accuracy, 88%; AUC, 0.94; 95% CI, 0.92-0.96; p < 0.001; n = 106 early-stage validation cohort, accuracy, 81%; AUC, 0.89; 95% CI, 0.83-0.95; p < 0.001), independent of age of the individuals, smoking habits, whole-blood storage time, and various inflammatory conditions. PSO enabled selection of gene panels to diagnose cancer from TEPs, suggesting that swarm intelligence may also benefit the optimization of diagnostics readout of other liquid biopsy biosources.


Assuntos
Algoritmos , Inteligência Artificial , Plaquetas/fisiologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Diagnóstico por Computador/métodos , Neoplasias Pulmonares/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais , Carcinoma Pulmonar de Células não Pequenas/sangue , Carcinoma Pulmonar de Células não Pequenas/genética , Estudos de Coortes , Feminino , Perfilação da Expressão Gênica , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Inflamação/sangue , Inflamação/diagnóstico , Inflamação/genética , Neoplasias Pulmonares/sangue , Neoplasias Pulmonares/genética , Masculino , Pessoa de Meia-Idade , Máquina de Vetores de Suporte
20.
Med Phys ; 44(9): 4859-4868, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28543540

RESUMO

PURPOSE: The objective of this study is to develop a computational model for simulating 915 MHz microwave ablation (MWA), and verify the simulation predictions of transient temperature profiles against experimental measurements. Due to the limited experimental data characterizing temperature-dependent changes of tissue dielectric properties at 915 MHz, we comparatively assess two temperature-dependent approaches of modeling of dielectric properties: model A- piecewise linear temperature dependencies based on existing, but limited, experimental data, and model B- similar to model A, but augmented with linear decrease in electrical conductivity above 95 °C, as guided by our experimental measurements. METHODS: The finite element method was used to simulate MWA procedures in liver with a clinical 915 MHz ablation applicator. A coupled electromagnetic-thermal solver incorporating temperature-dependent tissue biophysical properties of liver was implemented. Predictions of the transient temperature profiles and ablation zone dimensions for both model A and model B were compared against experimental measurements in ex vivo bovine liver tissue. Broadband dielectric properties of tissue within different regions of the ablation zone were measured and reported at 915 MHz and 2.45 GHz. RESULTS: Model B yielded peak tissue temperatures in closer agreement with experimental measurements, attributed to the inclusion of decrease in electrical conductivity at elevated temperature. The simulated transverse diameters of the ablation zone predicted by both models were greater than experimental measurements, which may be in part due to the lack of a tissue shrinkage model. At both considered power levels, predictions of transverse ablation zone diameters were in closer agreement with measurements for model B (max. discrepancy of 5 mm at 60 W, and 3 mm at 30 W), compared to model A (max. discrepancy of 9 mm at 60 W, and 6 mm at 30 W). Ablation zone lengths with both models were within 2 mm at 30 W, but overestimated by up to 10 mm at 60 W. CONCLUSIONS: The inclusion of decreased electrical conductivity above 95 °C, implemented with model B as guided by our experimental measurements, may be a good approach for approximating the dynamic changes that occur during MWA at 915 MHz. Although a step toward more effectively modeling MWA at 915 MHz, further investigation of the transition in dielectric properties with temperature and tissue shrinkage, especially at high temperatures is needed for more accurate simulations.


Assuntos
Técnicas de Ablação , Simulação por Computador , Fígado/efeitos da radiação , Micro-Ondas , Temperatura , Animais , Bovinos , Análise de Elementos Finitos , Temperatura Alta , Técnicas In Vitro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...